400 W metal halide to LED: what wattage replaces it in a parking lot?
There is no single LED wattage that equals a 400 W metal halide parking lot light. Compare the light the old and new fixtures actually deliver (lumens out of the fixture, and where the optic sends them), not the watts, and then check the new fixture on your existing poles against the light levels the lot needs.
Retailers label LED fixtures of quite different wattages as “400 W metal halide equivalent”. They cannot all be right for your lot, because watts measure power in, not light on the pavement.
Why isn't there a fixed LED equivalent for 400 W metal halide?
Because the number on the old lamp is not the light that reaches the ground. Three things sit between them:
- Lamp lumens drop over life, and with burn position. A common 400 W metal halide lamp is rated at 24,000 design mean lumens burning vertically, and 6–10 % lower burning horizontally (Philips MH400/U/ED28 datasheet).
- The old fixture loses some of that light inside its housing. For HID fixtures, the U.S. Department of Energy calculates the light leaving the fixture as luminaire efficiency × lamp lumens; LED fixtures are rated for the complete luminaire, so their lumens are already the light that leaves it (DOE FEMP Parking Lot Lighting Guide, p. 3). Comparing an LED fixture's lumens with a metal halide lamp's lumens compares two different things.
- The “400 W” is not what the fixture draws. A standard 400 W metal halide ballast (ANSI M59) is rated at 455 W input (Philips Advance 71A6091 datasheet).
Is lumens-to-lumens enough?
No. Two fixtures with similar lumens can light the same lot very differently. In a DOE example on one parking lot layout, a 250 W pulse-start metal halide fixture delivered 14,725 lumens at 288 W; an LED fixture delivered 10,758 lumens at 147 W. The LED design had 27 % fewer lumens, yet a slightly higher minimum (0.4 fc against 0.3 fc) and much better uniformity (max:min 14:1 against 35:1), because its optic spread the light more evenly (DOE FEMP guide, pp. 15–16; initial values, no light loss factor, judged against the older IES RP-20-98).
So lumens tell you whether a fixture is in the right range. The distribution type, the pole height and spacing you already have, and the targets the lot must meet decide whether it works.
What about utility rebate wattage limits?
They limit power, not light. For example, one utility's 2021 rebate table pays for replacing a 400 W HID fixture with an LED fixture of 175 W or less, and a 1000 W HID fixture with one of 400 W or less, if the fixture is DLC or Energy Star listed (Avista, 2021 exterior lighting rebate changes). A fixture under the cap can still leave dark spots between your poles. Check your own utility's current table, then check the light.
How do I pick the LED wattage for my lot?
- Find out what the lot must meet. Usually a minimum on the pavement and a uniformity ratio, from the specification, the local code or the IES recommendation (the IES values are on parking lot lighting requirements).
- Shortlist 2–4 LED fixtures by lumens and distribution, not by “equivalent” labels, and get their IES files.
- Check them on the poles you have, point by point, with the real pole positions and mounting heights. A one-for-one swap may not meet your targets even when the lumens look right; the DOE guide warns of exactly this when specific light levels and uniformity ratios are targeted (more in LED retrofit on existing poles).
- Pick the lowest wattage that passes, and keep the calculation with the quote.
How do I check the swap before I order fixtures?
With Runnax's hosted tool, on the poles that are already there:
- Upload the site plan as a PNG or JPEG, set the scale and check it with three lines of known length, draw the areas to light, and place the existing poles with their mounting heights.
- Upload the IES files of the 2 to 4 LED fixtures you are considering; each file is checked before you can enable it. You can keep one model on some poles and another on others.
- Enter the targets for each area, or judge all areas together.
- Among your candidates, and within the tilt and orientation ranges you allow, it picks the luminaire and aiming that meet your targets, or tells you none meets them in that range. When several pass, it keeps the one with the lowest total declared input power from the IES files, and the result says whether every lower-power combination was checked.
- You get a result page, a customer report (HTML and PDF) and a ZIP with point-by-point CSVs and an installation table.
How accurate is it? On a real parking-lot project with given poles, a research run of our engine agreed with AGi32 at 473 of 473 grid points for horizontal illuminance, largest difference 0.13 %. That run has not yet been repeated in the hosted tool. It is reported by us, not independently reviewed; details and what failed are on verification.
Can it tell me how much energy I'll save?
No. It reports the declared input power of the fixtures you choose, from their IES files; it does not estimate energy or dollar savings.
Can it work from my old AGi32 file or a CAD drawing?
Not today. The site plan is an image: export the drawing as a PNG or JPEG and trace the areas and poles by hand. It also does not move existing poles, does not choose pole heights, and calculates direct light only (no reflections, obstructions or terrain). Full list: facts.
Who this is for
Contractors quoting a metal halide to LED change-out on an existing lot (for contractors), manufacturers or reps choosing their own fixtures for a customer's existing poles (for lighting manufacturers), and owners or facility managers who want to check a quote before they buy.