A municipal sports-complex parking lot, South Dakota
The customer, a public works department working with an outside engineering consultant, asked for a lighting design for a sports-complex parking lot. The design was produced and delivered in AGi32. We then ran the same lot through the Runnax engine to see whether it reaches the same verdict on its own.
What the customer asked for
- Average illuminance
- Eavg ≥ 1.0 fc
- Uniformity
- Avg:Min ≤ 3.3
- Luminaire
- 75 W, 13,000 lm, 3000 K, mounted at 25 ft · 15 heads
- Calculation grid
- 271 points, 20 ft spacing, at grade, light loss factor 1.0
The criteria come from the customer's email and were confirmed by the project's sales engineer; we don't hold the original specification document.
Results on the same 271 points
| Eavg | Avg:Min | Verdict | Headroom | |
|---|---|---|---|---|
| Delivered design (AGi32) | 1.2159 fc | 3.1998 | Pass | 3.04 % |
| Runnax engine | 1.2367 fc | 3.1312 | Pass | 5.11 % |
Headroom is the tighter of the two criteria. The engine reads 1.7 % higher on average than the delivered file. Against an AGi32 direct-light run of the same lot, the engine's minimum, average and maximum agree within 0.5 % (details). Values are computed from all 271 unrounded points; rounding the report's displayed values first would give a different uniformity.
The customer accepted the design and placed the order.
Recomputed from the AGi32 file
We also recomputed the lot straight from its AGi32 (.AGI) file: every luminaire and its aiming, the photometric data AGi32 used, the light loss factor and all 271 calculation points, read from the file itself. It took about 4 seconds.
| AGi32, direct light | Runnax | |
|---|---|---|
| Average | 1.2366 fc | 1.2367 fc |
| Minimum | 0.3946 fc | 0.3949 fc |
| Maximum | 4.7930 fc | 4.7935 fc |
| Largest difference at any point | 0.32 % of the average | |
The recomputation also flags what the file assumes. This one uses a light loss factor of 1.0: no lamp or dirt depreciation. At 0.9 the average would be about 1.11 fc against the 1.0 fc the customer asked for: still a pass, with less room. On three real AGi32 parking-lot files, zone averages agree within 0.06 % (details).
Limits of this case
- Direct light only, like AGi32's direct-light calculation it is compared with.
- The delivered report's figures (1.2159 fc average) are 1.7 % below AGi32's own direct-light calculation of the same lot (1.2366 fc), which Runnax reproduces.
- Not an RP-8 or code-compliance statement.
- The 3.04 % headroom belongs to this lot. It says nothing about lots with less margin.
File intake for checks and research runs is paused. The hosted tool calculates on the poles you place: Start free trial →