LED retrofit on existing parking lot poles: will the new fixtures meet your light levels?

Last updated 2026-11-10 · sources linked · simulation, not a field measurement

Not automatically. Keeping the existing poles is usually the cheapest way to retrofit a parking lot, but a one-for-one fixture swap can miss your minimum or uniformity targets, so check the swap with a point-by-point calculation on the real pole positions before you quote it.

Should a parking lot LED retrofit keep the existing poles?

Usually, if you can. The U.S. Department of Energy's FEMP parking lot lighting guide says the cost of trenching, foundations and the poles themselves can often exceed the cost of the luminaires, and recommends reusing the pole locations, and even the poles, in a retrofit (DOE FEMP, Lighting for Parking Lots, Construction Tip).

Does a one-for-one LED replacement meet the same light levels?

Not always. The same DOE guide warns that one-for-one replacement may not be an option when specific light levels and uniformity ratios are targeted, because even distribution and spacing drive the result (DOE FEMP guide, Step 2).

Can changing the tilt or orientation fix uniformity without new poles?

Sometimes. In one Tennessee retrofit described in Buildings magazine, a one-for-one replacement on the same pole positions gave a max-to-min ratio of 30:1; adjusting tilt and orientation brought it down to 15:1 (Buildings, Etzler, 2018-11-27). That is one project, not a rule; whether aiming is enough on your lot depends on the poles, the fixtures and your targets, which is what a calculation answers.

What light levels should the retrofit meet?

The targets your customer or the local code sets. For the IES reference values (RP-8-25 with Errata 1 and 2: minimum horizontal illuminance, max:min ratio), see parking lot lighting requirements. Local codes and ordinances can replace the IES values, and some cities require a photometric study when fixtures are replaced (for example Wheaton, IL); check with the jurisdiction.

How do I check a fixture swap before I quote it?

With Runnax's hosted tool, on the poles that are already there:

  1. Upload the site plan as a PNG or JPEG (what image works), set the scale and check it with three lines of known length (one sets the scale, one horizontal and one vertical check it), draw the areas to light, and place the existing poles with their mounting heights.
  2. Upload the IES files of the fixtures you are considering; each file is checked before you can enable it.
  3. Enter the targets for each area, or judge all areas together.
  4. Run it. Among the 2 to 4 candidates you choose, and within the tilt and orientation ranges you allow, it picks the luminaire and aiming that meet your targets, or tells you none meets them in that range. When several pass, it keeps the one with the lowest total declared input power from the IES files, and the result says whether every lower-power combination was checked.

You can also assign a different model to each pole position, for example where some heads stay and some are replaced, and optionally report direct light at sample points on the property line against limits you enter.

What do I get to send to the customer?

A result page, a customer report (HTML and PDF) and a ZIP package with point-by-point CSVs, an installation table and the layout basis, in English or Chinese. The report says it is a simulation, not a field measurement and not a compliance check.

How accurate is it against AGi32?

On a real parking-lot project with given poles, a research run of our engine agreed with AGi32 at 473 of 473 grid points for horizontal illuminance, largest difference 0.13 %. That run has not yet been repeated in the hosted tool. It is reported by us, not independently reviewed, and the same page lists what failed (one tilt comparison) and what is not validated yet: verification. All facts and limits: facts.

What it does not do

It does not read CAD, PDF or AGi32 files (the site plan is an image), does not move existing poles, and does not choose pole heights. Only direct light is calculated: no reflections, obstructions or terrain.

Who this is for

Contractors quoting LED retrofits on existing lots (for contractors) and manufacturers or reps choosing their own fixtures for a customer's existing poles (for lighting manufacturers).

Try it free with your own IES files: sign up with an email link, 30 calculations per organization, up to 5 per day.